Home  /  Business Apps  / Short Circuit Fault Current on Windows Pc

Short Circuit Fault Current on Windows Pc

Developed By: ARCAD INC.

License: FREE

Rating: 0/5 - 29 votes

Last Updated: 2024-01-24

Sponsored Links

App Details

Version 1.0.18
Size Vwd
Release Date Jun 12, 2015
Category Business Apps

What's New:
New ... [see more]

Description:
Short Circuit Analytic version 1.0 mobile app performs available ... [read more]

Permissions:
View details [see more ]

QR-Code link:
[see more ]

Trusted App:
[see more ]


Compatible with Windows 7/8/10 Pc & Laptop

Download on PC

Compatible with Android

Download on Android

See older versions

App preview ([see all 5 screenshots])

App preview

Looking for a way to Download Short Circuit Fault Current for Windows 10/8/7 PC? You are in the correct place then. Keep reading this article to get to know how you can Download and Install one of the best Business App Short Circuit Fault Current for PC.

Most of the apps available on Google play store or iOS Appstore are made exclusively for mobile platforms. But do you know you can still use any of your favorite Android or iOS apps on your laptop even if the official version for PC platform not available? Yes, they do exits a few simple tricks you can use to install Android apps on Windows machine and use them as you use on Android smartphones.

Here in this article, we will list down different ways to Download Short Circuit Fault Current on PC in a step by step guide. So before jumping into it, let’s see the technical specifications of Short Circuit Fault Current.

Short Circuit Fault Current for PC – Technical Specifications

NameShort Circuit Fault Current
Installations10,000+
Developed ByARCAD INC.

Short Circuit Fault Current is on the top of the list of Business category apps on Google Playstore. It has got really good rating points and reviews. Currently, Short Circuit Fault Current for Windows has got over 10,000+ App installations and 0 star average user aggregate rating points.

Short Circuit Fault Current Download for PC Windows 10/8/7 Laptop:

Most of the apps these days are developed only for the mobile platform. Games and apps like PUBG, Subway surfers, Snapseed, Beauty Plus, etc. are available for Android and iOS platforms only. But Android emulators allow us to use all these apps on PC as well.

So even if the official version of Short Circuit Fault Current for PC not available, you can still use it with the help of Emulators. Here in this article, we are gonna present to you two of the popular Android emulators to use Short Circuit Fault Current on PC.

Short Circuit Fault Current Download for PC Windows 10/8/7 – Method 1:

Bluestacks is one of the coolest and widely used Emulator to run Android applications on your Windows PC. Bluestacks software is even available for Mac OS as well. We are going to use Bluestacks in this method to Download and Install Short Circuit Fault Current for PC Windows 10/8/7 Laptop. Let’s start our step by step installation guide.

  • Step 1: Download the Bluestacks 5 software from the below link, if you haven’t installed it earlier – Download Bluestacks for PC
  • Step 2: Installation procedure is quite simple and straight-forward. After successful installation, open Bluestacks emulator.
  • Step 3: It may take some time to load the Bluestacks app initially. Once it is opened, you should be able to see the Home screen of Bluestacks.
  • Step 4: Google play store comes pre-installed in Bluestacks. On the home screen, find Playstore and double click on the icon to open it.
  • Step 5: Now search for the App you want to install on your PC. In our case search for Short Circuit Fault Current to install on PC.
  • Step 6: Once you click on the Install button, Short Circuit Fault Current will be installed automatically on Bluestacks. You can find the App under list of installed apps in Bluestacks.

Now you can just double click on the App icon in bluestacks and start using Short Circuit Fault Current App on your laptop. You can use the App the same way you use it on your Android or iOS smartphones.

If you have an APK file, then there is an option in Bluestacks to Import APK file. You don’t need to go to Google Playstore and install the game. However, using the standard method to Install any android applications is recommended.

The latest version of Bluestacks comes with a lot of stunning features. Bluestacks4 is literally 6X faster than the Samsung Galaxy J7 smartphone. So using Bluestacks is the recommended way to install Short Circuit Fault Current on PC. You need to have a minimum configuration PC to use Bluestacks. Otherwise, you may face loading issues while playing high-end games like PUBG

Short Circuit Fault Current Download for PC Windows 10/8/7 – Method 2:

Yet another popular Android emulator which is gaining a lot of attention in recent times is MEmu play. It is super flexible, fast and exclusively designed for gaming purposes. Now we will see how to Download Short Circuit Fault Current for PC Windows 10 or 8 or 7 laptop using MemuPlay.

  • Step 1: Download and Install MemuPlay on your PC. Here is the Download link for you – Memu Play Website. Open the official website and download the software.
  • Step 2: Once the emulator is installed, just open it and find Google Playstore App icon on the home screen of Memuplay. Just double tap on that to open.
  • Step 3: Now search for Short Circuit Fault Current App on Google playstore. Find the official App from ARCAD INC. developer and click on the Install button.
  • Step 4: Upon successful installation, you can find Short Circuit Fault Current on the home screen of MEmu Play.

MemuPlay is simple and easy to use application. It is very lightweight compared to Bluestacks. As it is designed for Gaming purposes, you can play high-end games like PUBG, Mini Militia, Temple Run, etc.

Short Circuit Fault Current for PC – Conclusion:

Short Circuit Fault Current has got enormous popularity with it’s simple yet effective interface. We have listed down two of the best methods to Install Short Circuit Fault Current on PC Windows laptop. Both the mentioned emulators are popular to use Apps on PC. You can follow any of these methods to get Short Circuit Fault Current for Windows 10 PC.

We are concluding this article on Short Circuit Fault Current Download for PC with this. If you have any queries or facing any issues while installing Emulators or Short Circuit Fault Current for Windows, do let us know through comments. We will be glad to help you out!

We are always ready to guide you to run Short Circuit Fault Current on your pc, if you encounter an error, please enter the information below to send notifications and wait for the earliest response from us.

Email:

Message:


New features and performance improvements.
Showing permissions for all versions of this app

    This app has access to:

  • Phone
  • read phone status and identity.
  • Photos/Media/Files
  • modify or delete the contents of your USB storage.
    read the contents of your USB storage.
  • Storage
  • modify or delete the contents of your USB storage.
    read the contents of your USB storage.
  • Device ID & call information
  • read phone status and identity.
  • Other
  • Google Play license check.
    full network access.
Safe to Download

Napkforpc.com and the download link of this app are 100% safe. All download links of apps listed on Napkforpc.com are from Google Play Store or submitted by users. For the app from Google Play Store, Napkforpc.com won't modify it in any way. For the app submitted by users, Napkforpc.com will verify its APK signature safety before release it on our website.

Short Circuit Analytic version 1.0 mobile app performs available short circuit fault current calculations in three-phase radial power system you are working with. The app takes into consideration all of the key electrical parameters of power distribution system including power supply, cables, transformers, generators and motors.

The source can be set as a transformer supply or a busbar with a specified short circuit level. If a transformer source is used, the short circuit level on the primary side can be set to infinity by setting the data field blank.

Add components one by one to build up a single line diagram. The components can be cables, transformers, ligting loads, electrical devices, motors and generators. After a component has been added, its data can be edited by tapping the component when displayed on the screen.

Tap on 'Run Analysis' button to calculate available 3-phase and phase-to-phase short circuit current values and fault X/R ratio at each busbar.

Additional information about SCA V1.0 mobile and the comprehensive method for short circuit analysis

Simple point-to-point short circuit fault current calculations are carried out using Ohm's law and equipment resistance values. To determine fault current at various locations within power system, the system characteristics such as available short circuit value at service entrance, line voltage, transformer KVA rating and percent impedance, conductor characteristics are utilized.

The calculations become more complicated when resistance values are replaced with an impedance values. For instance, transformer ratio of reactance to resistance (X/R) is used along with transformer percent impedance to determine X and R values on a per unit bases. Similarly, the impedance for conductors within the electrical system are also broken down into X and R components of the impedance.

The peak asymmetric fault current is also determined by X/R ratio. The total asymmetric current is a measure of the total DC component and the symmetrical component. The asymmetrical component decays with time and will cause the first cycle of a fault current to be larger in magnitude than the steady-state fault current. Also, the decay of the DC component depends on the X/R ratio of the circuit between the source and the fault.

Knowing the fault X/R ratio is essential when selecting electrical and protection equipment. For example, all low-voltage protective devices are tested at predetermined X/R ratios. If the calculated X/R ratio at any given point in the electrical distribution system exceeds the tested X/R ratio of the overcurrent protective device, alternate gear with adequate X/R rating should be considered or the device effective rating must be reduced.

Features and Capabilities:

1. Calculate 3-phase, phase-to-phase short circuit currents at each bus within your power distribution system
2. Determine maximum available short circuit current, the amount of maximum upstream short circuit current and the minimum available short circuit current contributed by one source only. Both the available short circuit current (ASCC) and the part of ASCC through protection device current values are required for comprehensive arc flash hazard analysis using NFPA 70E and IEEE 1584 methods
3. Compute contributions from generators and motors
4. Add North American wire gauge cables as well as international cables
5. Perform comprehensive short circuit analysis by taking into account both active and reactive parts of equipment impedance
6. Determine fault X/R ratio at each bus
7. Save, rename, duplicate single-line diagrams and equipment data
8. Export, import one-line diagrams and all the equipment data for easy sharing
9. Send calculation results and captured single-line diagrams by email